Model number Operating modes Sample time Price Lead time Comments
Flex03LQ-01 Single MT-64 multiple tau 1.56ns $11,000 in stock AxA or AxB, 4x as high resolution Auto/cross

Option to record photon history simultaneously.

  Dual MT-32 multiple tau 1.56ns     Dual (AxA, BxB or AxB, BxA), 2x as high resolution Auto/cross

Option to record photon history simultaneously.

  Quad MT-16 multiple tau 1.56ns     Quad (AxA, BxB, AxB, BxA) standard resolution

Option to record photon history simultaneously.

  Quad auto MT-16 multiple tau 160ns     Quad (AxA, BxB, CxC, DxD) standard resolution
  Photon history recorder 60MHz     Intensity limit 10MHz
  Single tau 8 bit 1M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 1M), 1024 data points
  Single tau 8 bit 2M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
  Single tau 16 bit 1M Selectable from 12.4 to 1638 microseconds     Single sample time, arbitary delay (0 to 1M), 1022 data points
  Single tau 32 bit 2M Selectable from 1 to 107000 milliseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
Flex03LQ-8 Single MT-64 multiple tau 8ns $10,000 in stock AxA or AxB, 4x as high resolution Auto/cross

Option to record photon history simultaneously.

  Dual MT-32 multiple tau 8ns     Dual (AxA, BxB or AxB, BxA), 2x as high resolution Auto/cross

Option to record photon history simultaneously.

  Quad MT-16 multiple tau 8ns     Quad (AxA, BxB, AxB, BxA) standard resolution

Option to record photon history simultaneously.

  Quad auto MT-16 multiple tau 160ns     Quad (AxA, BxB, CxC, DxD) standard resolution

Option to record photon history simultaneously.

  Photon history recorder 60MHz     Intensity limit 10 MHz
  Single tau 8 bit 1M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 1M), 1024 data points
  Single tau 8 bit 2M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
  Single tau 16 bit 1M Selectable from 12.4 to 1638 microseconds     Single sample time, arbitary delay (0 to 1M), 1022 data points
  Single tau 32 bit 2M Selectable from 1 to 107000 milliseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
Flex03LQ-12 Single MT-64 multiple tau 12.5ns $9,500 in stock AxA or AxB, 4x as high resolution Auto/cross

Option to record photon history simultaneously.

  Dual MT-32 multiple tau 12.5ns     Dual (AxA, BxB or AxB, BxA), 2x as high resolution Auto/cross

Option to record photon history simultaneously.

  Quad MT-16 multiple tau 12.5ns     Quad (AxA, BxB, AxB, BxA) standard resolution

Option to record photon history simultaneously.

  Quad auto MT-16 multiple tau 320ns     Quad (AxA, BxB, CxC, DxD) standard resolution

Option to record photon history simultaneously.

  Photon history recorder 60MHz     Intensity limit 10MHz
  Single tau 8 bit 1M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 1M), 1024 data points
  Single tau 8 bit 2M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
  Single tau 16 bit 1M Selectable from 12.4 to 1638 microseconds     Single sample time, arbitary delay (0 to 1M), 1022 data points
  Single tau 32 bit 2M Selectable from 1 to 107000 milliseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
 