Model number Operating modes Sample time Price Lead time Comments
Flex01LQ-05 Single MT-64 multiple tau 5ns $13,000 in stock AxA or AxB, 4x as high resolution Auto/cross
  Dual MT-32 multiple tau 5ns     Dual (AxA, BxB or AxB, BxA), 2x as high resolution Auto/cross
  Quad MT-16 multiple tau 5ns     Quad (AxA, BxB, AxB, BxA) standard resolution
  Quad auto MT-16 multiple tau 160ns     Quad (AxA, BxB, CxC, DxD) standard resolution
  Photon history recorder 60MHz     Intensity limit 910KHz
  Dual channel recorder 40MHz     Intensity limit 450KHz
  Single tau 8 bit 1M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 1M), 1024 data points
  Single tau 8 bit 2M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
  Single tau 16 bit 1M Selectable from 12.4 to 1638 microseconds     Single sample time, arbitary delay (0 to 1M), 1022 data points
  Single tau 32 bit 2M Selectable from 1 to 107000 milliseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
Flex01LQ-08 Single MT-64 multiple tau 8ns $12,000 in stock AxA or AxB, 4x as high resolution Auto/cross
  Dual MT-32 multiple tau 8ns     Dual (AxA, BxB or AxB, BxA), 2x as high resolution Auto/cross
  Quad MT-16 multiple tau 8ns     Quad (AxA, BxB, AxB, BxA) standard resolution
  Quad auto MT-16 multiple tau 256ns     Quad (AxA, BxB, CxC, DxD) standard resolution
  Photon history recorder 60MHz     Intensity limit 910KHz
  Dual channel recorder 40MHz     Intensity limit 450KHz
  Single tau 8 bit 1M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 1M), 1024 data points
  Single tau 8 bit 2M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
  Single tau 16 bit 1M Selectable from 12.4 to 1638 microseconds     Single sample time, arbitary delay (0 to 1M), 1022 data points
  Single tau 32 bit 2M Selectable from 1 to 107000 milliseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
Flex01LQ-12 Single MT-64 multiple tau 12.5ns $11,000 in stock AxA or AxB, 4x as high resolution Auto/cross
  Dual MT-32 multiple tau 12.5ns     Dual (AxA, BxB or AxB, BxA), 2x as high resolution Auto/cross
  Quad MT-16 multiple tau 12.5ns     Quad (AxA, BxB, AxB, BxA) standard resolution
  Quad auto MT-16 multiple tau 320ns     Quad (AxA, BxB, CxC, DxD) standard resolution
  Photon history recorder 60MHz     Intensity limit 910KHz
  Dual channel recorder 40MHz     Intensity limit 450KHz
  Single tau 8 bit 1M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 1M), 1024 data points
  Single tau 8 bit 2M Selectable from 0.4 to 102 microseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
  Single tau 16 bit 1M Selectable from 12.4 to 1638 microseconds     Single sample time, arbitary delay (0 to 1M), 1022 data points
  Single tau 32 bit 2M Selectable from 1 to 107000 milliseconds     Single sample time, arbitary delay (0 to 2M), 1024 data points
 

กก

Send mail to Info@correlator.com with questions or comments about this web site.
Copyright ?1998 Correlator.com
Last modified: July 01, 2011